Method · Repair & strengthening

Fill the void, carry the load.

Grout poured or pumped into large voids under machine baseplates, at precast joints and in columns and beams. Non-shrink grout, cured as directed, does not shrink and bonds tightly.

What it is

What it is

Grout poured or pumped into large voids — under machine baseplates, at joints between precast blocks, in columns and beams — using formwork or pressure.

Choose it when

Large voids in a column, beam or machine base.

Keep in mind

Non-shrink grout does not shrink when mixed and cured as directed; epoxy grout is high-strength and resists chemicals and vibration.

Steps (in order of work)

  1. Pre-wet the substrate

    For cementitious grout the concrete is soaked first, and standing water is removed before the pour.

  2. Set the formwork

    Formwork closes the void so the grout stays where it is poured.

  3. Pour or pump the grout

    Poured in, or pumped under pressure, to fill the void completely; then left to cure before it takes load.

Under machine baseplates the grout carries the machine, so the base is loaded only after curing.

This is one example. We decide the actual work after seeing the site.

How we install & check

Diagnose before repair

We find the cause — corrosion, movement, leakage or overload — and pick the method for it.

Pick the method by the symptom

We find the cause first, then pick the method for it — not just "cover it up".

MethodWhat it doesSymptom
Patching — Surface RepairHand-fill chipped/spalled areas. No formwork; about 30–50 mm per layer by product (less overhead). Polymer-modified repair mortar.Chipped / spalled surface
Grouting — Filling Voidsthis pagePour or pump into large voids in columns, beams, machine bases (formwork / pressure). Non-shrink grout (no shrink when cured as directed, tight bond) ・ Epoxy grout (high strength, resists chemicals and vibration).Large void in a column, beam or machine base
Crack Injection — Epoxy or PU resinEpoxy resin restores strength in dry cracks ・ wetter cracks take flexible PU resin, which seals but does not restore strength.Structural crack — restore strength
Crack Injection — Stop leaks: PU FoamFoams on contact with water and stops it fast.Crack that leaks water
Crack Injection — Stop leaks: HydrogelSwells into a soft, flexible gel — for leaks at joints that move a little.Leak at a moving joint
CFRP StrengtheningNot repair — the goal is to increase the load a structure can carry (e.g. raise a floor's load capacity). 3 forms: Fabric/Wrap ・ Plate/Laminate ・ Rod/Bar. Requires structural-engineer design (ACI 440.2); damaged concrete is repaired first.Need to carry more load

Projects

Also with this method:Cardinal Health · MEA Khlong Toei

Questions

What decides the price?

The volume of the voids, how many places, the formwork needed and whether the grout must be pumped. Send drawings and photos on LINE.

Non-shrink grout or epoxy grout?

Non-shrink grout does not shrink when mixed and cured as directed, and bonds tightly. Epoxy grout is high-strength, resists chemicals and vibration, and goes on dry concrete.

When can the machine go back on?

Under a baseplate the grout carries the machine, so it is loaded only after the grout has cured.